FEATURES
 
1. Connection Establishment:
   – Specifically crafted for connecting impulse lines and transmitters.
   – 1/2″ female NPT connections with a center distance of 54mm (2 1/8″).
   – Two block valves, two equalizer valves, and one bleed valve with two vent connections, or alternative configuration available.
2. Pressure and Temperature Performance:
   – Operates at 6000 PSI with PTFE packing; Graf oil offered for elevated temperatures.
– Materials compliant with NACE MR-0-175 specifications can be customized.
3. Quality Assurance and Testing:
   – Thorough ultrasonic cleaning before assembly.
   – Pneumatic seat test at 1000 PSI using Nitrogen Gas.
   – Hydrostatic shell test at 1.5 times the working pressure.